Products

Power Guard 6-12v Series
6 -12 Year Design Life in Float Service

General Specifications and Technical Data Sheets
PS Model Number Design Life in Float Service at 20 Deg o C Nominal Voltage Nominal Capacity Dimensions (mm) (Length, Width, Height) Terminal Type Data Sheets
    (volts) C20 (Ah) L W H overall H    
PG-12V5.4 6-9 12 5.4 151 50 99 99 F1/F2 Download data sheet
PG-12V6 6-9 12 6.0 90 70 101 107 F2 Download data sheet
PG-12V7.6 6-9 12 7.6 151 65 94 100 F2 Download data sheet
PG-12V14 6-9 12 14 151 98 95 101 F2 Download data sheet
PG-12V21 6-9 12 21 181 77 167 167.5 T12 Download data sheet
PG-12V28 12 12 26 165 125 175 182 T12 Download data sheet
PG-12V30 12 12 30 166 176 125 125 T12 Download data sheet
PG-12V45 12 12 45 197 165 170 170 T6 Download data sheet
PG-12V60 12 12 60 229 138 205 216 T6 Download data sheet
PG-12V65 12 12 65 259 168 208 216 T6 Download data sheet
PG-12V80 12 12 80 259 168 208 216 T6 Download data sheet
PG-12V100 12 12 98 305 168 210 216 T6 Download data sheet
PG-12V110 12 12 111 330 173 212 220 T6 Download data sheet
PG-12V130 12 12 130 410 177 225 225 T6 Download data sheet
PG-12V150 12 12 154 344 171 274 280 T7 Download data sheet
PG-12V160 12 12 166 485 170 242 242 T7 Download data sheet
PG-12V220 12 12 226 522 240 218 224 T8 Download data sheet
PG-6V220 12 6 226 322 178 228 234 T8 Download data sheet

PDF icon Download summary sheet of all Power Guard Series products

Power-Sonic Europe manufactures a large range of 2v cells of various designs of which only the most popular types are shown here. Specifications are for guidance only, so please contact us for information on our full range, detailed specifications and applications advice. 

Terminal Detail
F2 Faston
NB Terminal Posts SP Spring Terminals
WL Insulated Wire Leads  

 

Features
  • Sealed Maintenance Free
    Valve regulated, spill proof construction allows trouble free, safe operation in any position, except continuous use in the inverted position. The sealed system eliminates electrolyte checking and water addition. The gases generated are recombined internally during normal use.
  • Shelf Life and Storage
    Special vents, high purity lead and grid alloys assure a low self-discharge rate and consequently a long shelf life. Lower Storage temperatures enhance shelf life characteristics even further.
  • Long Service Life
    Thick plate design based on sturdy lead-calcium grids and advanced paste technology yield design life of up to 10 years in standby applications
  • Standby Use
    The float Service Life, or life expectancy under continuous float charge at 2.25vpc at 20 deg is 5 years for batteries up to 26ah and 10 years for batteries with capacities greater than 30 ah
  • Cyclic Use
    The number of charge /discharge cycles depends on the capacity taken from the battery (a function of discharge rate and depth of discharge) operating temperature and charging method.
  • Design Flexibility
    Batteries may be used in series and/or parallel to give you choice of voltage and capacity.
  • Compact Design
    Power _sonic Batteries utilise the state of the art design, highest grade materials, and a carefully controlled plate making process to provide excellent output per cell.
  • Designed-in Reliability
    Cutting edge, manufacturing and process control combined with strict quality assurance procedures guarantee consistent and dependable performance.
  • Wide Operating Temperature Range
    Charge -15 to 50° C
    Discharge -15 to 60° C
    Storage -20° to + 50° C (in fully charged condition)
Electrical Characteristics
Charging Characteristics grph
Self discharge characteristics  

 

Battery Construction
  • Sealed, maintenance-free
  • Gelled Thixotropic electrolyte
  • Leak proof design
  • High conductivity terminals
  • High integrity terminal seals including compression grommet
  • Low pressure non return rubber valves
  • Low resistance micro porous glass separators
  • Special grid alloys for prolonged service Life
  • ABS plastic containers
Standards
  • Non Spill able Classification
  • IATA Approved as Non Hazardous
  • Available to BS6290 Part 4
  • Manufactured  to ISO 900
Applications
  • Photovoltaic / Solar / Wind
  • Telecommunications
  • Cycling / Float service
  • Wheelchair / Electric vehicle
  • Boats/Marine/Navigational Aids
  • Portable medical equipment
  • Golf